S'abonner

Risque NR : moyens des services d’incendie et de secours (SIS) et décontamination en 2022 - 06/06/23

RN risks: Resources of the fire and rescue services and decontamination in 2022

Doi : 10.1016/j.pxur.2023.02.001 
Denis Josse a, , Philippe Sans b, Christophe Poirier c, Alexandre Lacoste d, Aurélien Pays d, Cédric Pasquier e, Vincent Bassimon f, Jean-Charles Quevillon f, Sylvain de Freitas g
a SDIS 06., 140, avenue du Maréchal-de-Lattre-de-Tassigny, 06270 Villeneuve-Loubet, France 
b SDIS 31., 49, chemin de l’Armurie, 31770 Colomiers, France 
c SDIS44., 12, rue Arago, ZAC de Gesvrine, 44240 La Chapelle-sur-Erdre, France 
d BMPM., 9, boulevard de Strasbourg, 13003 Marseille, France 
e SDMIS., 17, rue Rabelais, 69003 Lyon, France 
f SDIS59., 18, rue de Pas, 59028 Lille, France 
g ENSOSP., 1070, rue du Lieutenant-Parayre, 13290 Aix-en-Provence, France 

Auteur correspondant : SDIS 06., 140, avenue du Maréchal-de-Lattre-de-Tassigny, 06270 Villeneuve-Loubet, France.SDIS 06.140, avenue du Maréchal-de-Lattre-de-TassignyVilleneuve-Loubet06270France

Résumé

La majorité des Services d’incendie et de secours (SIS) disposent de cellules mobiles d’intervention radiologique (CMIR) dont les moyens en équipements de protection, de détection, de prélèvement, d’identification et de décontamination permettent d’évaluer les risques, de localiser et confiner une source radioactive, et d’en limiter les effets sur l’homme et son environnement. Les risques radiologiques les plus courants auxquels les sapeurs-pompiers font face comprennent la découverte fortuite de matières radioactives et les accidents de transport. L’utilisation malveillante de produits radioactifs est aussi prise en compte par les services d’intervention qui, en cas de plan d’urgence, s’appuieront notamment sur l’expertise de l’Institut de radioprotection et de sûreté nucléaire (IRSN). Certains SIS sont dotés de moyens nationaux, par exemple des portiques de contrôle de contamination, permettant de répondre à des accidents d’ampleur. La prise en charge médicochirurgicale de victimes radio-contaminées catégorisées UA est prioritaire sur la décontamination. La décontamination d’urgence ciblera en priorité les plaies et les muqueuses afin d’éviter que la contamination externe ne devienne interne. Des dispositifs spécifiquement développés telles que la crème Calixarene (CEVIDRA) et les lingettes imprégnées DECPOL®RAD (OUVRY) complètent les moyens de décontamination d’urgence mis à disposition des intervenants. L’information et la préparation des populations à la gestion des risques radiologiques et nucléaires sont cruciales pour améliorer l’efficience de la réponse.

Le texte complet de cet article est disponible en PDF.

Summary

The majority of Fire and Rescue Services (FRS) have radiological response mobile units with protection, detection, sampling, identification and decontamination capacities that enable risks assessment, radioactive source location and containment, and mitigation of human and environmental effects. The most common radiological risks that firefighters face include incidental finding of radioactive materials and transportation accidents. Malicious use of radioactive compounds is also considered by emergency responders who can rely on expert services such as the Institute for Radiological Protection and Nuclear Safety. A few FRS have national capacities such as radiation portal monitors, allowing to respond to major accidents. Medico-surgical care of radiocontaminated victims sorted “immediate/priority 1” is a priority over decontamination. Emergency decontamination will primarily target wounds and mucous membranes in order to avoid that external contamination becomes internal. Specifically developed products such as the cream Calixarene (CEVIDRA) and the wet wipe DECPOL®RAD (OUVRY) complement responders emergency decontamination equipments. Information and preparation of populations for nuclear and radioactive risks management are crucial for improving the response efficiency.

Le texte complet de cet article est disponible en PDF.

Mots clés : Risques nucléaires et radiologiques, Moyens des sapeurs-pompiers, Décontamination

Keywords : Radiological and nuclear risks, Firefighters capacities, Decontamination


Plan


© 2023  Société Française de Médecine de Catastrophe. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 7 - N° 2

P. 129-134 - juin 2023 Retour au numéro
Article précédent Article précédent
  • Dotation hospitalière en moyens de détection et de protection
  • Jean-Michel Dindart, Jean-Sebastien Durand, Stéphane Gillet, Frédérique Pribat, Sébastien Buj, Didier Maocec, Stéphanie Mora
| Article suivant Article suivant
  • Risque NR, spécificités pédiatriques
  • Laurent Gabilly, Hélène Coignard, Aurélie Le Bagousse

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.